WELDING CABLE STRUCTURE
Generally conforms to, Based on CENELEC HD 22-6 31, VDE 0282, IEC 245-6, BS 6899, IS 6830/84,
IS 9857:1990
Conductor:
High conductivity, bare annealed copper flexible conductor, EC copper class 5 and class 6 generally conforms to IEC 60228, DIN VDE 0281
Insulation:
NBR Insulated flexible Nitrile rubber (NBR) insulated
Colour code:
Orange & Black Jacket
*Any other Color on specific request can also be supplied
WELDING CABLE FEATURES
TECHNICAL DATA TABLE
Current Rating :
The maximum current ratings of flexible welding cables for different duly cycles are based on an ambient air temperature of 25°c and a maximum conductor temperature of 90°c. The percentage duly cycles for various processes and applications are as follows:
Voltage Drop : When total cable lengths in excess of 15 mtrs., are involved, it may be necessary to use cables of larger cross section to ensure that the voltage drop is not excessive and welding currents are maintained at adequate levels.
TECHNICAL INFORMATION
Cross Sectional Area | Copper Construction | Nominal Thickness | Outer Dia Appx. | Max. Conductor Resistance at 20˚C | Current rating | |||||
Welding applications | ||||||||||
Duty Cycle | ||||||||||
100% | 85% | 80% | 60% | 35% | 20% | |||||
Sq. mm. | Nos. / Dia. mm | mm | mm | Ω/km | amp | amp | amp | amp | amp | amp |
10 | 322 / 0.20 | 2.00 | 8.10 | 1.910 | 100 | 100 | 100 | 101 | 106 | 118 |
16 | 511 / 0.20 | 2.00 | 9.10 | 1.210 | 135 | 136 | 136 | 139 | 150 | 174 |
25 | 798 / 0.20 | 2.00 | 10.60 | 0.780 | 180 | 182 | 183 | 190 | 213 | 254 |
35 | 1121 / 0.20 | 2.00 | 11.80 | 0.554 | 225 | 229 | 231 | 243 | 279 | 338 |
50 | 1596 / 0.20 | 2.20 | 13.70 | 0.386 | 285 | 293 | 296 | 316 | 371 | 457 |
70 | 2220 / 0.20 | 2.40 | 16.60 | 0.272 | 355 | 367 | 373 | 403 | 482 | 602 |
95 | 1349 / 0.30 | 2.60 | 18.20 | 0.206 | 430 | 448 | 456 | 498 | 606 | 765 |
120 | 608 / 0.50 | 2.80 | 21.60 | 0.161 | 500 | 524 | 534 | 587 | 721 | 917 |
150 | 760 / 0.50 | 3.00 | 24.00 | 0.129 | 580 | 610 | 622 | 689 | 853 | 1090 |
185 | 943 / 0.50 | 3.20 | 26.30 | 0.106 | 665 | 702 | 717 | 797 | 995 | 1277 |
240 | 1225 / 0.50 | 3.50 | 29.20 | 0.0801 | 710 | 770 | 916 | 1296 | 1587 | 744 |
300 | 1498 / 0.50 | 3.60 | 31.70 | 0.0641 | 800 | 850 | 1035 | 1450 | 1790 | 840 |
400 | 2035 / 0.50 | 3.80 | 36.00 | 0.0486 | 925 | 1000 | 1195 | 1690 | 2070 | 970 |
> All are flexible conductor
> Insulation material is HOFR
Rating factors for variation in ambient temprature
Ambient temperature °C | 20° | 25° | 30° | 35° | 40° | 45° | 50° | 55° | 60° | 65° |
Rating Factor | 1.04 | 1.00 | 0.96 | 0.91 | 0.87 | 0.82 | 0.76 | 0.69 | 0.64 | 0.57 |