CONDUCTOR
EC Grade Annealed Copper With High Flexibility Class 5 and Uniform Resistance Properties.
INSULATION
All Insulation Grades In PVC exceeds the requirements As Stated In Is 5831. All Grades Of Insulation Are "RoHS" Compliant With 70°c And 85°c Rating
MARKING
The cables are printed with generic marking AXELON
INSULATION COLOURS
Red, Yellow, Blue, Green, Black, Yellow / Green, Grey, White. Other colors available on request.
SHEATH COLOURS
Black, Ivory, Blue, White other colors available on request.
PACKING
Standard packing of 100 mtr. in coils. Longer length available on request
MULTICORE FLEXIBLES
Type of Insulation | Type of Sheathing | Applicable Standards | Typical Applications |
---|---|---|---|
Standard PVC | Standard PVC, HRPVC | IS 694, BS 6500, IEC 60227, DIN VDE-0281 |
Power Cords for appliance, temporary power supplies. 3 core flat cables are suitable for submersible pump applications. |
Heat Resistant PVC up to 105°c | Standard PVC, HRPVC | IS 694, BS 6500, IEC 60227, DIN VDE-0281 |
Hi-power appliances, ovens, temporary power supply in higher temperature areas. |
Standard PVC of FRLS | FRLS (Flame Retardant Low Smoke) | IS 694, BS 6500, IEC 60227, DIN VDE-0281, IEC 60754-1, IEC 60332-1, BS-4066-1, ASTMD 2843, ASTMD - 2863 |
Power cords for application used in fire prone areas, flame proof equipments, machine tools used in critical locations and heat zones. |
SIZE, DIMENSIONS & RATINGS
Size Sq. mm |
No/Nomial Dia Of Conductor Strands* mm |
Nominal Insulation Thickness(mm) mm |
Nominal Thickness of Sheath | Approx. Overall diameter | Voltage /Amp per mtr. |
Max. D.C. Conductor Resistance at 20°c ohms |
||||||||
2 core mm |
3 core mm |
4 core mm |
5 core mm |
2 core mm |
3 core mm |
4 core mm |
5 core mm |
Current Rating amps |
DC or single phase AC mv |
3 Phase AC mv |
||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.50 | 16/0.20 | 0.6 | 0.9 | 0.9 | 0.9 | 0.9 | 6.9 | 7.3 | 8.0 | 8.7 | 4.0 | 83.0 | 72.0 | 39.0 |
0.75 | 24/0.20 | 0.6 | 0.9 | 0.9 | 0.9 | 0.9 | 7.3 | 7.7 | 8.4 | 9.2 | 7.0 | 56.0 | 48.0 | 26.0 |
1.00 | 32/0.20 | 0.6 | 0.9 | 0.9 | 0.9 | 1.0 | 7.6 | 8.1 | 8.8 | 9.6 | 11.0 | 43.0 | 37.0 | 19.5 |
1.50 | 30/0.25 | 0.6 | 0.9 | 0.9 | 1.0 | 1.0 | 8.9 | 9.4 | 10.4 | 11.4 | 14.0 | 31.0 | 26.0 | 13.3 |
2.50 | 50/0.25 | 0.7 | 1.0 | 1.0 | 1.0 | 1.0 | 10.3 | 10.9 | 12.0 | 13.2 | 19.0 | 18.0 | 16.0 | 7.98 |
4.00 | 56/0.30 | 0.8 | 1.0 | 1.0 | 1.0 | 1.1 | 11.6 | 12.4 | 13.6 | 15.3 | 26.0 | 11.0 | 9.6 | 4.95 |
6.00 | 84/0.30 | 0.8 | 1.1 | 1.2 | 1.2 | 13.0 | 13.8 | 15.5 | 0.0 | 33.0 | 7.3 | 6.0 | 3.3 | |
10.00 | 141/0.30 | 1.0 | 1.3 | 1.4 | 1.4 | 16.5 | 17.7 | 19.5 | 0.0 | 45.0 | 4.4 | 3.5 | 1.91 | |
16.00 | 226/0.30 | 1.0 | 1.4 | 1.4 | 1.4 | 19.4 | 20.6 | 23.0 | 0.0 | 60.0 | 2.8 | 2.2 | 1.21 | |
25.00 | 196/0.40 | 1.2 | 1.4 | 1.5 | 1.6 | 23.8 | 25.6 | 28.5 | 0.0 | 75.0 | 0.2 | 1.4 | 0.78 | |
35.00 | 276/0.40 | 1.2 | 1.6 | 1.6 | 1.7 | 27.2 | 29.3 | 32.7 | 0.0 | 95.0 | 0.2 | 1.0 | 0.554 | |
50.00 | 396/0.40 | 1.4 | 2.0 | 2.0 | 2.0 | 32.0 | 34.6 | 38.6 | 0.0 | 125.0 | 0.2 | 0.8 | 0.386 | |
70.00 | 360/0.50 | 1.4 | 2.2 | 2.2 | 2.2 | 36.8 | 39.6 | 44.3 | 0.0 | 170.0 | 0.2 | 0.6 | 0.272 |
Note: * The number and diameter of conductor strands are for reference only. Conductor resistance as per IS:8130 is the governing criteria
The above data is indicative and may be revised without prior intimation. As per IS:3961 (Part V)-1968